ICC · Adopted Building Codes
- ICC. Defines minimum R-values by climate zone and location (attic, wall, floor). Table R402.1.2 is the residential insulation schedule. Basis for the zone selector and target R-value defaults.Cited by: Insulation calculator
- IRC R703 governs exterior wall covering, including minimum lap on wood siding and clearance from grade. Basis for the wood lap 6 in. exposure assumption (nominal 8 in. board with 1 in. minimum lap).Cited by: Siding calculator
- Authoritative source for asphalt shingle slope thresholds (R905.1.1), ice barrier requirements (R905.1.2), drip edge (R905.2.8.5), and high-wind fastening (R905.2.6). Free public viewer at ICC.Cited by: Roofing calculator
- Pool barrier requirements: 48 in. minimum height, self-closing/self-latching gate with latch 54 in. from ground. Appendix G adopted by local jurisdiction. Life-safety code.Cited by: Fencing calculator
- 2021 International Residential Code, free public viewer at ICC. Table R302.6 sets minimum gypsum thickness on each side of the garage separation; 5/8 inch Type X is required where habitable rooms sit above the garage.
- IRC 2021 Chapter 8. Prohibits air-permeable insulation in unvented attic assemblies. Requires air-impermeable insulation (spray foam) or a flash-and-batt hybrid. Enforced as a hard warning in this calculator.Cited by: Insulation calculator
ACI · ACI · American Concrete Institute
- American Concrete Institute. Defines minimum thicknesses, reinforcement schedules, and aspect-ratio limits for residential concrete slabs. Paid standard; the ACI store page is the canonical link. For free residential slab guidance, see the NRMCA CIP series below.Cited by: Concrete slab calculator
ANSI · ANSI · American National Standards Institute
- ANSI A108.02 Section 4.3.8.1: large-format tiles (any side over 15 in.) shall not exceed 33% running-bond offset. Enforced as a hard warning in this calculator.Cited by: Tile calculator
ASTM · ASTM · ASTM International
- Defines Grade SW (severe weathering) and Grade MW (moderate weathering) classifications for facing brick. Grade SW required in weathering index 50 or greater. Current edition: C216-26.Cited by: Brick calculator
- Wind resistance classification: Class G to 120 mph, Class H to 150 mph. Required reference for high-wind zones at 140 mph and above.Cited by: Roofing calculator
- Specifies maximum 10 ft post spacing for residential chain-link fencing. Defines terminal post (end, corner, gate) vs. line post requirements.Cited by: Fencing calculator
AWC · AWC · American Wood Council
- Free PDF from the American Wood Council. The authoritative reference for exterior wood deck stringers. Caps cut 2x12 stringers at 6 feet of run and requires at least 5 inches of solid wood below the tread cut.Cited by: Stair calculator
- Structural design reference for wood construction. Span tables, fastener schedules, and load calculations. This calculator does not perform structural analysis.Cited by: Lumber calculator
BIA · BIA · Brick Industry Association
- Bricks-per-square-foot tables by unit size at standard 3/8 in. mortar joints. Basis for the Queen, King, Norman, Roman, and Utility coursing constants.Cited by: Brick calculator
- Vertical expansion joints at 20-25 ft intervals. The 20 ft default is the conservative end and is what the calculator uses.Cited by: Brick calculator
- Running, stack, Flemish, and English bonds. Basis for the waste percentages by bond pattern in the calculator.Cited by: Brick calculator
- Selection and quality assurance for Type N, S, M masonry mortars. Basis for the 80 lb pre-mixed bag covering ~33 bricks at a 3/8 in. joint.Cited by: Brick calculator
NRMCA · NRMCA · National Ready Mixed Concrete
- National Ready Mixed Concrete Association reference library on ready-mix delivery, short-load fees, and pour preparation.Cited by: Concrete slab calculator
EXT · University Extension Services
- Clemson Cooperative Extension. Recommends wood and bark mulches at 2 to 3 in. depth and advises keeping mulch 2 to 3 in. away from the stems of woody plants; do not pile against the trunk. Primary reference for the volcano warning. Does not publish bag sizes or a settlement percentage.Cited by: Mulch calculator
- Penn State Cooperative Extension. Confirms finely shredded mulches decompose faster and require more frequent replenishment. Does not quantify a year-one volume-loss figure; the 25 percent settlement constant in the calculator is a landscape trade rule-of-thumb, not a PSU value.Cited by: Mulch calculator
MFG · Manufacturer Technical Data
- Cross-check on the premium tier coverage band. Aura posts the same 350 to 400 square feet per gallon.Cited by: Paint calculator
- Standard tier cross-reference. Regal Select is the industry benchmark for an eggshell or satin finish that hides in two coats on a smooth previously painted wall.Cited by: Paint calculator
- The self-adhered leak barrier category page. WeatherWatch and StormGuard land here at ~200 square feet per roll. Required at eaves in IRC-defined cold climates.Cited by: Roofing calculator
- Pre-cut starter strip, 120 linear feet per bundle. Required at eaves to seal the first shingle course.Cited by: Roofing calculator
- The synthetic underlayment category page. FeltBuster and Deck-Armor land here at 1000 square feet per roll, the underlayment line-item standard on a modern asphalt roof.Cited by: Roofing calculator
- Pre-cut hip and ridge cap, 25 linear feet per bundle. Required at every ridge and hip; 3-tab shingles cut into thirds are no longer code-compliant on most products.Cited by: Roofing calculator
- The architectural shingle benchmark. 3 bundles per square at 33.3 sf per bundle, exposure 5 5/8 inches. The volume product on residential roofing in North America.Cited by: Roofing calculator
- Standard tier coverage reference. Published 350 to 400 square feet per gallon at 4 mils wet film. The volume eggshell and satin product on residential interiors.Cited by: Paint calculator
- Premium tier coverage reference. Published 350 to 400 square feet per gallon, identical band to ProMar 200 and Cashmere. Premium paints hide better on the first pass; they do not stretch further.Cited by: Paint calculator
- Budget tier coverage reference. Published 350 to 400 square feet per gallon at 4 mils wet film.Cited by: Paint calculator
- Product page confirms the 4.5-gallon, 63.7 lb pail and coverage data used for the compound math.
TRD · Industry & Trade Publications
- Voluntary product standard for softwood lumber. Defines nominal-to-actual size conversions. A '2x4' is 1.5 x 3.5 in. actual.Cited by: Lumber calculator
- Defines pressure-treatment use categories. UC3B for above-grade exterior, UC4A for ground contact, UC4B for ground contact heavy duty.Cited by: Lumber calculator
- Plain-English walkthrough of IRC R311.7 with the exact subsection numbers. Useful cross-reference when the codes.iccsafe.org viewer is paywalled.Cited by: Stair calculator
- National utility-locating service. Required by law in all 50 states before digging post holes. Free for homeowners. 2-3 business day lead time.Cited by: Fencing calculator
- Trade association for loose-fill cellulose. Publishes the ~18% settlement factor from installed to settled depth that drives the dual-depth display and the FTC Rule 460 labeling requirement.Cited by: Insulation calculator
- 25 lb bag yields ~0.14 ft3 (~242 in3). Grout bag count is computed from joint-volume geometry, not a flat lookup, because consumption varies dramatically with tile size.Cited by: Tile calculator
- 50 lb modified thinset. Coverage by trowel size: 1/4×1/4 in. ~95 sf, 1/2×1/2 in. ~50 sf, 3/4×3/4 in. ~30 sf. Basis for the thinset bag count on the spec slip.Cited by: Tile calculator
- EPA's public program page covering lead-safe work practices in pre-1978 target housing, certified firm requirements, and handouts for homeowners. Links to the 40 CFR Part 745 Subpart E regulation text and to the state-level administering programs.Cited by: Paint calculator
- Federal C and D debris guidance. Several states restrict gypsum from the general waste stream because of hydrogen sulfide off-gassing in wet landfills.Cited by: Drywall calculator
- Source of the 15 percent loose-to-compacted shrink factor that drives the base-course waste default.Cited by: Gravel calculator
- The authoritative reference on unpaved road structure, compaction behavior, and maintenance. Free PDF from the Federal Highway Administration.Cited by: Gravel calculator
- Density and coverage reference for decomposed granite, which runs denser than clean aggregate due to fines.Cited by: Gravel calculator
- 30 lb bag coverage: ~40 sqft at 10 in. depth. Basis for the cellulose bag count and installed-depth math.Cited by: Insulation calculator
- GA-214-2021 released as a free download. Defines L0 through L5, the industry vocabulary for finish quality.
- Current edition. Fastener spacing (12 in. o.c. ceilings, 16 in. o.c. walls at 16 in. framing), joint treatment, and finishing procedures. Supersedes GA-216-2010.
- North American Insulation Manufacturers Association. R-value per inch reference tables for fiberglass blown (2.2-2.7), batt (3.4-3.7), and general fiberglass guidance.Cited by: Insulation calculator
- ISA consumer guide. Covers the 2-4 in. depth standard, mulch-volcano damage, and the 6 in. trunk-clearance rule. Industry-standard reference for proper mulching technique.Cited by: Mulch calculator
- Product page for HardiePlank fiber cement lap siding. 12 ft planks, 8.25 in. width, 7 in. reveal after 1.25 in. blind-nail overlap (7 sqft coverage per plank). ASTM E136 noncombustible rating. Basis for the plank count on the spec slip.Cited by: Siding calculator
- Installation instructions, ICC-ES evaluation reports, and best-practice guides for HardiePlank and Hardie trim systems.Cited by: Siding calculator
- Primer coverage constant. New drywall is porous; PVA primer runs 300 to 400 square feet per gallon with 300 as the conservative floor.Cited by: Paint calculator
- Joint compound sanding is not in Table 1 but is covered by the performance option. Wet-sand or use a HEPA-attached sander.Cited by: Drywall calculator
- Industry trade association for vinyl siding. Defines the 'square' (100 sqft) as the standard ordering unit. Installation manuals cover thermal expansion float-nail requirements.Cited by: Siding calculator
- Yield 0.6 ft³/bag, the basis for the 80 lb bag count line on the spec slip.Cited by: Concrete slab calculator
- Retail bag volume reference. A 60 lb Sakrete pea gravel bag covers about 0.45 cubic feet.Cited by: Gravel calculator
- Tile Council of North America. Defines installation methods, mortar coverage requirements, grout joint minimums, and waste factors by pattern. The primary reference for tile takeoff methodology.Cited by: Tile calculator
- Building code requirements and specification for masonry structures. Referenced by IBC for structural masonry design. This calculator covers veneer only.Cited by: Brick calculator
- Free one-page PDF summarizing IRC R311.7.5.1 and R311.7.5.2 with the 3/8 inch variance rule spelled out.Cited by: Stair calculator
- Canonical reference for the Blondel stride formula (2R + T = 24 to 25 inches). Matches the Fine Homebuilding and NAHB comfort targets.Cited by: Stair calculator
Note · How this page is built
This index is generated at build time from the sources[] array on every calculator's content file. A single source cited by multiple calculators appears once with all citing calculators listed. When a calc adds or removes a source, this index rebuilds automatically.
Total citations across all calculators: 66. Total unique sources: 59. The difference is the reuse factor: sources that power more than one calculator.
Redline · scope notice Every source link goes directly to the publisher's official site. When a link breaks, report it to [email protected] and the calculator content will be updated in the next revision cycle.